2-inch guillotine gate for controlling the honey outlet from a honey tank or storage vessel.
Its wide passage and lever allow you to open, modulate and cut off the flow rate during transfer or filling of containers.
01 · OUTLET CONTROL
Fit the tap to a clean, rigid wall with its gasket seated correctly. Before filling the tank, test the closure and check that there is no play. Honey viscosity and temperature affect the actual flow rate; the tap controls it, but cannot make it identical for every batch.
02 · MAINTENANCE
Disassemble and clean the surfaces in contact with honey according to the procedure in your honey house. Check the seal and the closing area before reassembling: a crystallised residue can prevent the guillotine from seating correctly.
03 · BEFORE YOU BUY
The confirmed measurement is 50 mm internal and 60 mm external. Do not choose it based solely on the capacity or brand of the honey tank: check the hole, the wall thickness, the fixing system and the space to operate the lever.
| Reference | AS-010 |
|---|---|
| Type | Guillotine gate |
| Material | Food-grade plastic |
| Diameters | 50 mm internal / 60 mm external · 2 inches |
check_circle
check_circle