31 kW propane burner with a double gas-air mixture stabilising chamber and a thermocouple safety valve. It measures 41 × 41 × 45 cm.
At 31 kW, a single bottle ends up losing output. That figure decides how you set it up, and it explains why the maker advises having more than one.
01 · PROPANE AND 50 MBAR
It is built for propane and works with a 50 mbar regulator, connected to a bottle or a tank. The maker is explicit: it must not be used with a gas other than the one it was built for, because the gas-air mixture is calibrated for that calorific value and that pressure.
The double stabilising and compensating chamber is what holds that mixture steady while the burner runs at full load — which is exactly when a poorly fed burner starts giving an uneven flame.
02 · WHY MORE THAN ONE BOTTLE
At full power, 31 kW is, by our rough calculation, on the order of 2.4 kg of gas per hour. An ordinary bottle does not vaporise that much continuously: the liquid cools as it evaporates, the bottle frosts and the pressure drops — and what you notice is the burner 'losing strength' for no apparent reason.
The answer is not to turn the regulator up. The maker says that, on bottles, it is best to have more than one to swap when output drops, or to connect it to a propane tank; winter cold makes the effect worse.
03 · THE THERMOCOUPLE DOES NOT VENTILATE
The thermocouple safety valve cuts the gas if the flame goes out. That solves unburnt gas escaping, and it matters — but it does not solve ventilation: a 31 kW burner consumes oxygen and produces combustion gases in quantity.
The maker warns that it is for professionals only and for perfectly ventilated indoor spaces; a carbon monoxide detector is, on top of that, a precaution we recommend. The unit complies with Regulation (EU) 2016/426 and standards UNE EN 497, UNE EN 203-1 and UNE EN 203-2-1.
04 · WHICH POT IT TAKES
The 41 × 41 cm square spreads the flame under pots of 60 to 90 cm and batches of 200 to 500 litres, as the maker indicates. With a much smaller pot the flame escapes round the sides and output is wasted.
It takes a loaded pot of up to 200 kg; for more weight, the maker calls for separate supports. Made in Valencia.
05 · BEFORE YOU BUY
This is professional gas equipment: it needs a 50 mbar regulator, adequate ventilation and, at full load, more than one bottle.
| ✓ RIGHT FIT | Melting wax in volume, with 60-90 cm pots and a properly sized propane supply. |
| ✕ WRONG FIT | Small jobs, or a single bottle with no spare to swap: at 31 kW output drops. |
| ⚠ NOT INCLUDED | Regulator, hose, bottle or the melting pot. |
| Maximum output | 31 kW |
|---|---|
| Gas | Propane — no other gas |
| Pressure | 50 mbar regulator |
| Consumption at full power (our calculation) | On the order of 2.4 kg/h |
| Safety | Thermocouple valve: cuts the gas if the flame goes out |
| Size | 41 × 41 × 45 cm |
| Recommended pot | 60 to 90 cm across · batch capacity 200 to 500 l |
| Maximum load | Loaded pot up to 200 kg; heavier, with separate supports |
| Standards | Regulation (EU) 2016/426 · UNE EN 497 · UNE EN 203-1 · UNE EN 203-2-1 |
| Manufacturer | Flames VLC (Valencia), model M-400 |