FillOmat® Honey Level Alarm Sensor Honey pumps
FillOmat® Honey Level Alarm Sensor
57 .50
BR-31510

FillOmat® Honey Level Alarm Sensor

FillOmat® Honey Level Alarm Sensor Honey pumps
  • FillOmat® Honey Level Alarm Sensor Honey pumps
  • FillOmat® Honey Level Alarm Sensor Honey pumps
  • FillOmat® Honey Level Alarm Sensor Honey pumps
  • FillOmat® Honey Level Alarm Sensor Honey pumps
whatsapp Share in WhatsApp
57 .50
Tax included

Stock
Audible level alarm for attended honey transfer and filling, with an approximately 92 dB signal and adjustable clamp for vessel walls up to 29 mm. Uses a 9 V block battery, not included; warns the operator but does not stop the pump.
57 .50
Tax included

Stock
Quantity
Select options Options

Express Shipping

Return Guarantee

Safe payment

Details of FillOmat® Honey Level Alarm Sensor

≈ 92 dB

AUDIBLE ALARM

9 V

BLOCK BATTERY

≤ 29 mm

VESSEL WALL

MANUAL

OPERATOR RESPONSE

A level alarm that warns in time when a pail or tank approaches its limit while honey is being pumped or filled.

FillOmat sensor BR-31510 clamps to the rim with a stainless-steel bracket and locking screw, placing the level switch at the selected height. When honey reaches the detection point, the sounder emits an alarm of approximately 92 dB.

01 · FUNCTION

It warns; it does not stop the pump

This is a self-contained, battery-powered alarm. It attracts the operator's attention so they can close a valve, stop the pump or change the receiving vessel. The pictured set has no control connection to a filling machine, so it must not be treated as an automatic shut-off or as the sole safeguard in an unattended process. The FillOmat name identifies its intended use around that filling system; it does not demonstrate an electrical interlock.

02 · LEVEL SETTING

Allow for reaction time and run-on flow

Loosen the adjustment, place the switch at the required warning level and tighten the clamp onto a stable wall up to approximately 29 mm thick. Do not set it at the absolute rim: product continues to enter through the hose while the operator reacts, and foam or surface movement may occupy more space. Leave freeboard for the actual flow rate and first test with a controlled quantity. Keep the switch clear of the wall, lid, inlet jet and any moving part.

03 · BEFORE EACH BATCH

Test the battery, sound and switch movement

Fit a new or checked 9 V block battery —it is not supplied— and move the level switch by hand before filling. Confirm that the alarm can be heard from the normal working position while the machinery runs. An audible test alone does not validate the level: also check detector height and clamp security. If the sound weakens, the cable is damaged or the mechanism does not move freely, do not begin pumping until the fault has been corrected.

04 · HYGIENE AND STORAGE

Only the sensing area should contact honey

The bracket and level switch are stainless steel; the alarm enclosure and battery holder include plastic components and must remain outside the splash zone. Clean the product-contact part after every use without immersing the sounder or wetting the electrical connection. Dry completely before storage, avoid repeatedly bending the cable at either entry and remove the battery for long storage periods to prevent damage from leakage.

05 · BEFORE BUYING

Check the rim, reach and operating method

It suits open vessels whose rim can accept the clamp and processes where an operator remains nearby to respond. Confirm that the detector reaches the chosen level without fouling a lid, agitator, hose or incoming stream.

✓ SUITABLEAttended honey transfer or filling into open vessels with walls up to 29 mm.
✕ NOT APump shut-off, redundant overfill control or replacement for operator supervision.
⚠ NOT INCLUDED9 V block battery, pump connection or automatic stopping device.

TECHNICAL DATA

LTA referenceBR-31510
FunctionAudible alarm when honey reaches the set level
Alarm levelApproximately 92 dB
Power9 V block battery, not included
MountingLocking clamp for walls up to approximately 29 mm
MaterialStainless bracket and level switch; enclosure with plastic components
ResponseManual operator action; no demonstrated automatic pump stop
Intended useHoney level warning around FillOmat filling workflows