OXAVAR PROVAP® 220 Cleansers and Maintenance Accesories
OXAVAR PROVAP® 220
399 .00
439 .00
A961216

OXAVAR PROVAP® 220

starstarstarstarstar_half
See 10 Customer Reviews
  • -€40.00
OXAVAR PROVAP® 220 Cleansers and Maintenance Accesories
  • OXAVAR PROVAP® 220 Cleansers and Maintenance Accesories
  • OXAVAR PROVAP® 220 Cleansers and Maintenance Accesories
  • OXAVAR PROVAP® 220 Cleansers and Maintenance Accesories
  • OXAVAR PROVAP® 220 Cleansers and Maintenance Accesories
whatsapp Share in WhatsApp
399 .00
439 .00
Tax included

Stock
Mains-powered 220 V oxalic acid vaporiser, the original PROVAP model. Thermostat with on-screen reading and around 20 seconds per hive. Needs a 1,000 W inverter generator as a minimum and no more than 10 m of cable. Supplied with a measuring spoon and two pans. For use with registered veterinary medicines only; a respirator is essential.
399 .00
439 .00
Tax included

Stock
Quantity
Select options Options

Express Shipping

Return Guarantee

Safe payment

Details of OXAVAR PROVAP® 220

20 s

PER DOSE

230 °C

EMPTY PAN

1,000 W

MINIMUM GENERATOR

2

YEARS OF WARRANTY

Mains-powered 220 V oxalic acid vaporiser with a thermostat and an on-screen temperature reading, working each hive in around 20 seconds.

This is the original PROVAP model. Being electric it has no flame and no gas cartridge, so it is handled at the hive entrance without an open fire, and the thermostat is what lets you repeat the same temperature hive after hive.

01 · WORKING CYCLE

Two minutes of warm-up, then one hive every twenty seconds

You plug it in, it climbs to 230 °C in about two minutes and it stays on all day. Load the pan with the dose levelled off with the spoon, turn the unit over and insert it straight away. As the cold acid goes in, the plate drops to 210-215 °C: sublimation happens during that fall, and when the reading climbs back to 230 °C that hive is done.

02 · THE 230 °C QUESTION

The display reads the empty plate, not the acid

It is the question that comes up most: if oxalic acid sublimates from 157 °C and starts to break down above roughly 189 °C, why does the unit read 230 °C? Because that figure is the empty pan before you load it. A plate sitting at exactly 157 °C would have no heat in reserve to sublimate a dose in twenty seconds: it would cool on first contact and the cycle would stretch into minutes. The surplus is what gets spent heating the acid, which is why the reading falls as you load. What matters is not the peak of the empty plate but how long the product stays in contact with it, which here is seconds.

03 · POWER AT THE APIARY

Inverter generator and a short lead

It needs 1,000 W as a minimum, and inverter; above that power there is no problem, below it there is. A conventional set puts out dirty waveform and this unit carries control electronics. And one rule that gets overlooked: no more than 10 metres of cable from the generator. The voltage drop over a long lead does not just heat it less well, it can damage the unit.

04 · MAINTENANCE

Clean the pan at the end of the day

This model does not clog if you clean it; it clogs if you do not. At the end of the day, with the unit still switched on, add a little water to the pan and the residue lifts off by itself. Doing it hot and doing it daily is what stops a blockage mid-season. It comes with two pans, so you can swap one in while you clean the other.

05 · BEFORE YOU BUY

You work crouched at the hive entrance, and over a long run of hives that posture costs you more than the seconds you save: that is what the version with a steel bar and top loading is for, which is worked standing. And on very large apiaries, chaining doses without a pause means the element takes longer to recover and the rhythm drops.

✓ FITSSublimation with a registered medicine, on operations that value repeating the same temperature in every hive.
✕ DOESN'T FITWorking standing up, and using it without your own inverter generator or with more than 10 m of cable.

PRECAUTIONS

Registered medicines only. In Spain the only registered oxalic acid medicines that may be sublimated are Api-Bioxal and Varroxal; in other countries check what is authorised locally. The dose and the procedure are those on the current data sheet of whichever medicine you use — we do not set them.

The use of pure oxalic acid — as impregnated wipes, sublimated, or in home-made strips — is not an authorised application, and in Spain it carries criminal and administrative liability. This shop accepts no responsibility for improper use of the product.

A respirator is essential. Oxalic acid vapour is aggressive to the airways and the eyes. Always treat with proper protection and work with the wind behind you.

TECHNICAL DATA

ReferenceA961216
Power supply220 V · 1,000 W inverter generator or higher
Plate temperature230 °C empty, with on-screen reading
Warm-upAbout 2 minutes from switch-on
Time per doseAbout 20 seconds
Supplied withVaporiser, measuring spoon and 2 pans
Size and weight19.5 × 39.5 × 10 cm · 1 kg
Warranty2 years
6 Items

Data sheet

Hygiene and treatment article type
Vaporizers and sublimators

Reviews about OXAVAR PROVAP® 220

starstarstarstarstar_half
Ver
10
reviews
There are no ratings for the current language. Select all languages ​​to see all ratings.